Image

CLARIS N 2000

Delivers quality water for vending, coffee and steam applications. Part number: 4339-45

Image

The Claris series filter cartridges are only compatible with the CLARIS heads designed for them. In all cases, the cartridges can be connected to the water network with the help of the Claris heads. They cannot be used on their own! You can find more information about the heads on the CLARIS HEADS page.

Image

SPECIFICATIONS

  • Service Flow Rate
    Maximum 3.7 Lpm (1 gpm)

  • Rated Capacity
    5’380 L for hot beverages and vending
    4’890 L for steamers

    This capacity is based on total hardness at 10°dH (179 PPM)
    with bypass setting at 1 for hot beverages and vending and
    at 0 for steamers

  • Pressure Requirements
    10 - 125 psi (0.7 - 8.6 bar), non-shock

  • Temperature Limits
    4-30°C (39-86°F)

  • Overall Dimensions
    475 mm L x 175 mm D
Image

FEATURES • BENEFITS

+

Special focus on removing total hardness, stabilizing the water’s Ph

+

Very effective descaling capabilities combined with corrosion protection

+

Provides pH-neutral protection against calcification and the formation of gypsum

+

Integrated protection against growth of bacteria in the filter that can decrease product life

+

Reduce heavy metals such as lead, mercury, cadmium, copper and iron

+

NSF Certified under NSF/ANSI Standard 42

+

EU Food contact certified

+

Easy replacement without turning off the water supply (auto shut-off function)*

+

Bypass function with seven settings*

+

4-stage filtration process that includes:

  • Particle filter
  • Fine and microplastic filter
  • Activated carbon
  • Ion exchanger

Specially selected filter fleeces hold back dirt and particles, thus providing lasting filter protection even when water quality is poor.

Image

CLARIS
N 2000

  • Coffee
  • Vending
  • Hot Beverage
  • Steam applications
Image

DATA SHEET

CLARIS N water filter

Dimensions

Unit

500

1000

1500

2000

Internal filter volume

l

1.7

3.2

4.4

6.7

Filter height incl. filter head (A)

mm

475

410

525

525

Filter height (B)

mm

425

360

475

475

Max. filter head diameter (C)

mm

100

100

100

100

Max. filter diameter (D)

mm

95

136

136

175

Space for filter replacement (E)

mm

40

40

40

40

Weight

kg

1.8

3.2

4.3

6.5

Operating information

Unit

500

1000

1500

2000

Operating pressure (without pressure surges)

2-8 bar (29-116 psi)

Water temperature

4-30°C (39-86 °F)

Normal flow range*

l/h

15-240

15-240

15-240

15-240

Flow rate at a 0.5 bar drop in pressure

l/h

>150

>150

>150

>150

Installation position

vertical

Bypass system

7 settings (0-60%), setting 0-1 recommended

*For short-term consumption, a higher flow rate is possible

Capacity (in l)

°dH*

°Clarke
(GB)*

PPM*

°FH*

Bypass
level

500

1000

1500

2000

Steamer

10

13

179

18

0

1220

2180

3140

4890

Vending

10

13

179

18

1

1340

2400

3460

5380

*Total hardness

TECHNOLOGIES AND SOLUTIONS FOR WATER PURIFICATION

Innovative technologies – combined to suit any application

Particle filtration

+

+

+

+

Water softening

++

++

Mineral stabilization

++

pH balance

+

+

+

Chlorine reduction

+

+

+

+

Decarbonization

++

++

+

++

Heavy metal adsorption

++

++

++

++

Contaminant adsorption (organic)

+

+

+

Demineralization

+

Microplastics removal (≥5 μm)

+

+

+

+

Characteristic feature

Decarbonisation /
Partial desalination

S+Pholyphosphat

Softener

Complete desalination
+ Bypass

Products comparison CLARIS vs. BWT wam vs. BRITA

CLARIS N

Filtertype

Size

Capacity

Filtertype

Size

Capacity

Filtertype

Size

Capacity

-

-

-

BWT Bestprotect

S

600

BRITA Purity C Finest

-

-

CLARIS N

500

1340

BWT Bestprotect

V

1500

BRITA Purity C Finest

C150

1100

CLARIS N

1000

2400

BWT Bestprotect

M

2200

BRITA Purity C Finest

C300

1800

CLARIS N

1500

3460

BWT Bestprotect

XL

3590

BRITA Purity C Finest

C500

3414

CLARIS N

2000

5380

BWT Bestprotect

2XL

6000

BRITA Purity C Finest

C1100

6000

INSTALLATION TIPS

  • The system can be operated freestanding, lying horizonally or mounted vertically.

  • If mounting vertically to a wall, securely connect the mounting backet to the wall using suitable screws.

  • Water pressure at the filter system inlet must not exceed 8 bar (116 psi). A pressure reducer valve must be installed on the water supply side of the filter system if the inlet pressure exceeds 8 bar (116 psi).

  • Shutoff valve must be installed upstream of the filter.

  • Refer to Installation, Operation & Maintenance Manual for cartridge flushing and startup.

OPERATION TIPS

  • Change Claris N Cartridge when its precalculated water volume has been reached or at least once per year.

  • Change cartridges when capacity is reached.

  • Always flush the filter cartridge at time of installation and cartridge change.

  • Do not use hardness test strips to check for hardness reduction. Please use the Claris Titration Kit to check for hardness reduction.

SIZING

  • Service Flow Rate: Maximum 3.7 Lpm (1 gpm)

  • Rated Capacity:
    5’380 L for hot beverages and vending
    4’890 L for steamers

This capacity is based on total hardness
at 10°dH (179 PPM) with bypass setting at
1 for hot beverages and vending and at 0
for steamers



You are visiting the website of Swiss Electronic Ltd.
Pentair is a US-based company and a market leader in the manufacture of water filters and water filtration systems.
We are proud to be the official Hungarian distributor of Pentair Everpure Claris products. 
This product range can be used in households and in the HORECA segment. It is the perfect choice for filtering water for premium quality dishes and other brews, for gourmet coffee and tea making, and for supplying water to steamers.